Lochinvar water heater error codes

Freeze protection pump on. In order to prevent the water in the heater from freezing, the SMART SYSTEM control turns on the boiler pump whenever the inlet temperature goes below the minimum temperature. The range of this parameter is 32°F (0°C) to 104°F (40°C). The default value is 45°F (7°C).

Lochinvar water heater error codes. COMMERCIAL WATER HEATERS. CLD-09 ... 9/22 - Printed in USA DIMENSIONS & SPECIFICATIONS Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com For technical information call 800-722-2101. Lochinvar, LLC ... See "Element Availability Schedule" for letter codes and available voltage ...

Freeze protection pump on. In order to prevent the water in the heater from freezing, the SMART SYSTEM control turns on the boiler pump whenever the inlet temperature goes below the minimum temperature. The range of this parameter is 32°F (0°C) to 104°F (40°C). The default value is 45°F (7°C).

COMMERCIAL GAS WATER HEATERS LIGHT DUTY CHARGER GAS MODELS Lochinvar's commercial Light Duty Charger tank-type water heaters are available in 55, 74, and 98 gallon capacities. ... Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com For technical information call 800-722-2101 ...Hot Water Solutions Since 1939 | Lochinvar | LochinvarWith ARMOR, you can match one or more water heaters with inputs ranging from 150,000 to 285,000 with one or more storage tanks in a wide variety of sizes. Models From 150,000 to 285,000 Btu/Hr AWN400PM to AWN801PM / OUT OF PRODUCTIONAugust 2, 2023. Home Type Water Heater. Yes, lochinvar is a reliable and highly rated water heater brand. With advanced features and durable construction, lochinvar water heaters provide efficient and consistent performance for your hot water needs. Offering a wide range of models and options, lochinvar ensures that you can find the perfect ...Lochinvar Copper-Fin II CFN0992 Installation And Operation Manual (80 pages) Lochinvar Water Heater User Manual. Brand: Lochinvar | Category: Water Heater | Size: 7.97 MB.Boiler Lochinvar 45,000—500,000 Btu/hr Models Installation And Service Manual Water heater/domestic hot water supply boiler (48 pages) Boiler Lochinvar Copper-Fin 497 User's Information ManualPage 52 Installation & Service Manual Start-up Check flame and combustion Replace the flue sensor and grommet into the vent 1. Shut the water heater down by pressing the UP button for connection. five (5) seconds. Place the Shield water heater back into normal operation. 2.

This water heater complies with ANSI Z21.10.1-current ... CONTACT RESIDENTIAL TECHNICAL ASSISTANCE AT 1-615-889-8900 OR VIA E-MAIL AT [email protected]. — Do not store or use gasoline or other ... Fuel Gas Code as it relates to the installation of gas fired water heaters. The qualified technician must also be Connect a field supplied 3/4" diameter hose to a drain pan. Using field supplied means, cover the refractory in the back of the combustion chamber of the heat exchanger. 6. Use a vacuum cleaner to remove any accumulation on the water heater heating surfaces. Do not use any solvent. 1 Common Issues And Solutions. 1.1 No Hot Water: What To Do When Your Heater Stops Working. 1.2 Possible Causes And Troubleshooting Steps. 1.3 Checking For Error …COMMERCIAL REVERSE INDIRECT WATER HEATER Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com 3/21—Printed in U.S.A. U TOP VIEW A E D F B 1-1/2" NPT DHW Inlet Sensor/Thermometer Connections (Typ.) 3/4" Tank Relief Valve 1-1/2" NPT Domestic Hot Water Outlet 2" NPT Boiler ...These parameters can be changed by the installer by accessing the Set point 1 at High Outdoor Temp 1, Set point 2 at High Outdoor Temp 2 and Set point 3 at High Outdoor Temp 3 parameters. The temperature range of this parameter is 68°F (20°C) to 190°F (88°C). The default value is 70°F (21°C).

COMMERCIAL GAS WATER HEATERS LIGHT DUTY CHARGER GAS MODELS Lochinvar's commercial Light Duty Charger tank-type water heaters are available in 55, 74, and 98 gallon capacities. ... Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com For technical information call 800-722-2101 ...Lochinvar's Manufactured Home residential gas models are available in 30, ... • Code Compliance - Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act, (EPCA), as amended. ... water heater may NEVER be connected to any existingWith thermal efficiency of 85%, Power-Fin water heaters feature infinitely modulating burner firing rates (turndown), precisely matching the firing rate to domestic water load requirements. The result is better overall efficiency and less cycling. 7 Models from 500,000 - 2,000,000 Btu/Hr. 85% Thermal Efficiency. 5:1 Turndown Ratio.With ARMOR, you can match one or more water heaters with inputs ranging from 150,000 to 285,000 with one or more storage tanks in a wide variety of sizes. Models From 150,000 to 285,000 Btu/Hr AWN400PM to AWN801PM / OUT OF PRODUCTION

Hamden ct obituary.

STATUS LIGHT AND DIAGNOSTIC CODE TROUBLESHOOTING CHART (Continued) LED STATUS PROBLEM CORRECTIVE ACTION 4 FLASHES The Gas Control Valve’s Relight pilot and verify 4 flashes. If 4 flashes are temperature sensor has detected observed, turn Gas Control Valve/Thermostat knob that the water temperature was to OFF.Glass Lined Indirect Water Heater. The Glass Lined Indirect Water Heater provides an alternative to stainless steel lined tanks. 4 Models: Capacities from 40-119 Gallons. Glass Lined Steel Tank and Coil. Fully Welded Construction. Dent Resistant Jacket. 6-Year Limited Warranty. Technical Documents.Conclusion. In conclusion, Lochinvar Water Heaters are reliable and efficient for meeting your hot water wishes. With a focus on fine, innovation, and patron delight, Lochinvar continues to be a depended-on call in the industry. Whether you are searching for a residential or business solution, Lochinvar has a wide variety of merchandise to fit various requirements.The Knight wall mount control module receives input from boiler sensors. The control module activates and controls the blower and gas valve to regulate heat input and switches boiler, DHW and system pumps on and off as needed. The user/installer programs the module to meet system needs by adjusting control parameters.

View online or download Lochinvar Knight XL KBX0400N Installation & Operation Manual. Sign In Upload. Manuals; Brands; Lochinvar Manuals; ... System Water Piping Methods. 38. Low Water Cutoff Device. 38. Chilled Water System. 38. Freeze Protection. 38. ... Water Heater Boiler Gas Heater Swimming Pool Heater Heat Pump. More Lochinvar ManualsA comprehensive product range which provide efficient, reliable heating and hot water solutions for new-build or refurbishment requirements. Product Ranges. Configuration Chooser. Support. Condensing water heaters. Gas-fired boilers. Heat Pump packages. Electric Water Heaters.An error code like this is typically caused by air in the system.Hot Water Solutions Since 1939 | Lochinvar | LochinvarWhen your EcoSmart tankless water heater is getting water below 150 degrees, the display LED will illuminate or light with the desired set home temperature.View and Download Lochinvar PVL 07575 installation and operating manual online. POWER VENTED GAS WATER HEATERS SERIES 210/211. PVL 07575 water heater pdf manual download. Also for: Pvn 07575, Cvn075075, Cvl075075.Install the ferrule nut into the gas valve at the pilot tube location, hand tight only. Insert the pilot tube into the ferrule nut until the tube bottoms out, then tighten the nut with a 7/16" wrench until the crimp connection seals to the pilot tube. Continue to tighten until the nut is tight in the gas valve. 7.Install the ferrule nut into the gas valve at the pilot tube location, hand tight only. Insert the pilot tube into the ferrule nut until the tube bottoms out, then tighten the nut with a 7/16" wrench until the crimp connection seals to the pilot tube. Continue to tighten until the nut is tight in the gas valve. 7.Temperature range on residential gas water heater is from 110°F ±10° to 155°F ±10° and a 70°F vacation setting. The T&P valve will open at 195°F ± 10°. The water heater …Copper-fin II/IIE Boiler, Water Heater and Pool Heater 402 - 2072 - read user manual online or download in PDF format. Pages in total: 44. ... Lochinvar Copper-fin II/IIE Boiler, Water Heater and Pool Heater 402 - 2072 User Manual. Download. Like. Full screen Standard. Page of 44 Go.Manuals / Lochinvar / Household Appliance / Boiler Lochinvar 1.5, 3.5, 2.5 service manual Troubleshooting, Fault, Description, Corrective Action Models: 3.5 2.5 1.5. ... • Verify that the system is full of water and that all air . has been properly purged from the system. • Verify that the boiler is piped properly into the heating .

How To Fix Lochinvar Water Heater E12 Error Code (A Simplified Troubleshooting Guide!). In this video tutorial I will show you how to fix Lochinvar Water Hea...

The Lochinvar indirect water heater is a great choice for those who want a reliable and efficient unit. With a capacity of 80 gallons, this unit is perfect for families who want plenty of hot water. It's also Energy Star certified, so you can be sure you're getting a unit that will save you money on your energy bills.Lochinvar LLC 300 Maddox Simpson Pkwy, Lebanon, TN 37090. 1-615-889-8900 www.lochinvar.com Lochinvar Parts & Service Department 300 Maddox Simpson Pkwy, Lebanon, TN 37090. Phone: 615-889-8900 • Fax: 615-882-2918 Email: [email protected] the gas valve switch to the "OFF" position. Use a ruler to measure the distance from the base of the fan to the end of the air shutter (FIG. 2-7). Compare this distance to the specified "A" dimension for the pool heater in Table 2B. Turn all gas valve knobs and the manual gas cock to the "OFF" position.Lochinvar SNA201-100 - 90 Gallon - 199,999 BTU Shield Commercial Water Heater (Natural Gas)- The SHIELD commercial water heater delivers best-in-class innovation from Lochinvar. It operates at 96% thermal efficiency, and provides a 100% effective defense against a water heater's worst enemy - lime scale buildup inside the tank. <br><br> Lime scale buildup insulates the water from the heat ...Lochinvar Manuals; Water Heater; ARMOR 501; Lochinvar ARMOR 501 Manuals Manuals and User Guides for Lochinvar ARMOR 501. We have 1 Lochinvar ARMOR 501 manual available for free PDF download: Service Manual ... Water Heater Boiler Gas Heater Swimming Pool Heater Heat Pump. More Lochinvar ManualsI have a Lockinvar Hot water Boiler model #1. CHN1802 getting a fault code HSI Lockout Current LOWA? Is this a low water condition as the boiler keeps running.2. Water set point moved from 160 to 140 … read moreelectric water heaters offer a wide range of voltages and wattages and is ideal for low draw applications. COMMERCIAL WATER HEATERS. CLS-04 ... Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com For technical information call 800-722-2101. Lochinvar, LLCLochinvar GTN04040 - 40 Gallon - 40,000 BTU Energy Saver Residental Water Heater (Nat Gas)- Standard Features: Code Compliance - The Energy Saver residential gas water heater meets the National Appliance Energy Conservation Act (NAECA) Energy Factor requirements effective April 16, 2015. Meets the thermal efficiency and standby loss …

Lourdes walk in chenango bridge appointments.

Lori wachs daughter.

LIMITED RESIDENTIAL WATER HEATER WARRANTY ... plumbing, housing or building codes, or II) without a certified American Gas Association, ASME, or comparable combination temperature ... Lochinvar, LLC. • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000 www.Lochinvar.com RES-WAR-06Lochinvar Copper-Fin II CFN0752 Installation And Operation Manual (80 pages) Lochinvar Water Heater User Manual. Brand: Lochinvar | Category: Water Heater | Size: 7.97 MB.How To Fix Lochinvar Water Heater E12 Error Code (A Simplified Troubleshooting Guide!). In this video tutorial I will show you how to fix Lochinvar Water Hea...Call or contact Lochinvar LLC, 300 Maddox Simpson Pkwy, Lebanon, TN 37090. Phone: 1-615-889-8900 or visit our website at: www. lochinvar.com. The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed by the warrantor. Dealer replacements are made subject to in ...2.1 Describing The Symptoms Of Common Issues In Lochinvar Boilers. 3 Step 1: Basic Troubleshooting. 3.1 Outlining The Initial Steps To Take When Encountering A Problem. 3.2 Checking For Power Supply, Thermostat Settings, And Fuel Supply. 3.3 Explaining How To Reset The Boiler If Necessary.INSTALLATION AND SERVICE MANUAL. GAS HEATERS FOR COMMERCIAL POOL APPLICATIONS 500,000 - 2,070,000 Btu/hr MODELS Starting Serial #F0600187510. CPE-I-S-14. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.Maintaining your Rinnai water heater is essential for ensuring that it runs efficiently and safely. Here are some tips to help you keep your water heater in top condition: The firs...Temperature range on residential gas water heater is from 110°F ±10° to 155°F ±10° and a 70°F vacation setting. The T&P valve will open at 195°F ± 10°. The water heater temperature adjusting dial is factory set at the lowest temperature, all the way counter-clockwise to the mechanical stop, unless specified differently by provincial orZip Code* Message* Submit. Locations. Lochinvar, LLC World Headquarters ... 800-722-2101. Customer Assurance 877-554-5544. General Inquiries 615-889-8900. Lochinvar Ltd. (United Kingdom) 7 Lombard Way. The MXL Centre. ... We focus solely on serving the unique needs of each customer with a product portfolio including boilers, water heaters, pool ...DOMESTIC WATER HEATERS 495,000 - 2,065,000 Btu/hr MODELS CB-CW(E)-I-S-07. Hydronic Heating Boilers and Domestic Water Heaters 2 Table of Contents ... Gas Code, ANSI Z223.1 and/or CAN/CGA-B149 Installation Code. Where required by the authority having jurisdiction, theTemporary shutdown due to excessive exhaust temperature. Check the air supply, clear any blockages, and confirm vent lengths are within limits. CA. Combustion air in short supply. Check air supply, clear any blockages, and confirm vent lengths are within limits. Deciphering these codes helps us tackle issues head-on. ….

Temperature range on residential gas water heater is from 110°F ±10° to 155°F ±10° and a 70°F vacation setting. The T&P valve will open at 195°F ± 10°. The water heater …The bottom of the boiler has a 3/4 inch pipe for connection of a 3/4 inch PVC pipe (FIG. 2-2). Slope condensate tubing down and away from the boiler into a drain or condensate neutralizing filter. Condensate from the Noble Combi Boiler will be slightly acidic (typically with a pH from 3 to 5).Tall 40 MBH Residential Natural Gas Water Heater from Lochinvar At Ferguson. Ferguson is the #1 US plumbing supply company and a top distributor of HVAC parts, waterworks supplies, and MRO products. ... Tall 40 MBH Residential Natural Gas Water Heater Fast # Part # LPVN05040; Item # 4665332; ... Unavailable --Decrease quantity Quantity ...Copper-Fin II® Water Heaters. In 1993, Lochinvar introduced the first horizontal chassis, copper-finned tube water heater with fan-assisted combustion. 9 Models from 400,000 - 2,070,000 Btu/hr. 85% thermal efficiency. 4:1 Turndown Ratio. Gasketless Copper-Finned Tube Heat Exchanger. SMART SYSTEM™ Operating Control with a Built-in Cascade ...Let the air out of the waterline, replace the sensor. Code E04. Leak sensor detecting moisture or a leak. Detect the source of leakage, hire a professional. Code E06. Water temperature too high, faulty thermostat, faulty heating elements. Adjust the thermostat power, replace the thermostat and heating elements.C3 High limit thermostat activated Wait for water temperature to drop E6 Heater running in safe operation mode Contact Lochinvar Limited TABLE 1.1 DIAGNOSTIC CODES 1.3 ERROR CODES When a code is flashing in the LED display, the water heater has locked out and will need to be reset byLochinvar toll-free at 833-232-9706 from 8 a.m. to 8 p.m. ET Monday through Friday or online at www.lochinvar.com and click on "Recall Notices" at the bottom of the page. Consumers can also check for the recalled boilers' serial number at: www.waterheaterrecall.com, and select the look-up feature for the flue collector recall.Lochinvar's Grid-Capable residential electric models are available in 40 and 50 gallon ... CEC and HUD national codes. Certified to UL 174 for ... This is a 240 volt Tall Water Heater, 40 gallon capacity with upper 4500 watt and lower 4500 water elements. Lochinvar water heater error codes, Conclusion. In conclusion, Lochinvar Water Heaters are reliable and efficient for meeting your hot water wishes. With a focus on fine, innovation, and patron delight, Lochinvar continues to be a depended-on call in the industry. Whether you are searching for a residential or business solution, Lochinvar has a wide variety of merchandise to fit various requirements., Veritus Air Source Heat Pump Water Heater raises the bar on efficiency levels and maximizes energy savings. Multiple Veritus heat pumps can be banked together to achieve large commercial hot water demands, provide built-in redundancy, and match the capacity to the demand. Veritus takes installation flexibility to a whole new level., Any time an error, fault or function code is displayed, service will be required. Please Note: Any failure of the heat pump will result in an automatic switch to the resistance heat mode to ensure a constant supply of hot water. For service and support on the GeoSpring Hybrid Electric Water Heater, please contact 1-888-443-4394, Monday - Friday ..., Lochinvar WATER HEATERS manual . 1. 12. Download 12 pages, 298.73 Kb. 1 . STAINLESS STEEL INDIRECT ... Check Code List for Toshiba RAV-SP1102UT-E ..., Turn the gas valve switch to the “OFF” position. Use a ruler to measure the distance from the base of the fan to the end of the air shutter (FIG. 2-7). Compare this distance to the specified “A” dimension for the pool heater in Table 2B. Turn all gas valve knobs and the manual gas cock to the “OFF” position., Turn the main power switch to the "OFF" position. Shut off gas supply at the field installed manual gas cock in the gas piping to the appliance. If fuel supply is LP gas, shut off gas supply at the tank. On ER152 - ER202 models remove the 1/8" hex plug, located on the "inlet" side of the gas valve., View and Download Lochinvar Armor X2 AWN1000 installation & operation manual online. Armor X2 AWN1000 water heater pdf manual download. Also for: Armor x2 awn1500, Awl1000, Armor x2awl1300, Armor x2 …, Hot Water Solutions Since 1939 | Lochinvar | Lochinvar, One measurement while the water heater is not firing (static) and again while the water heater is firing (dynamic). If the supply gas pressure drops more than 1.5” W.C. between the static and dynamic pressure measurements, this may indicate the gas line and/or gas regulator to the water heater is undersized., Place the communication board onto the standoff s installed in Step 3. Use the screw (provided in kit) to secure the control panel cover (FIG. 2-6). 5. Connect the wire harnesses (100172824 , 100172826 and 100172828) from the appliance to the communication board following the diagram shown in FIG. 2-7. 6., You can test BRIEFLY by removing the vent pipe. If it starts your exhaust is most likely blocked and obstructed. Disclaimer : Running any gas appliance with the venting removed for anything other than brief testing purposes is extremely dangerous. Otherwise it could be a stuck open pressure switch, defective exhaust motor, or a broken/kinked hose., Step 1: On your Bosch tankless water heater, locate the control panel or display screen. Press the buttons labeled "+" or "-" to scroll through the options until you reach the recirculation program menu. Step 2: Once you are in the recirculation program menu, you will see different options displayed on the screen., Turn the main power switch to the "OFF" position. Shut off gas supply at the field installed manual gas cock in the gas piping to the appliance. If fuel supply is LP gas, shut off gas supply at the tank. On ER152 - ER202 models remove the 1/8" hex plug, located on the "inlet" side of the gas valve., Service Manual. Service Manual. Models: 80 - 285. Starting Serial #H07H10040039. This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual and the Knight Boiler Installation and Operation Manual, before installing. Perform steps in the order given., Lochinvar Copper-fin II/IIE Boiler and Water Heater 2072 User Manual • Troubleshooting • Lochinvar Water boiler Manuals Directory ManualsDir.com - online owner manuals library Search, Hot Water Solutions Since 1939 | Lochinvar | Lochinvar, Display Error Description Possible Solution; 10, 11,12, 13,14 - CH Supply Sensor fault S1 •Check wiring for break • Check for proper flow direction, Lochinvar GTN04040 - 40 Gallon - 40,000 BTU Energy Saver Residental Water Heater (Nat Gas)- Standard Features: Code Compliance - The Energy Saver residential gas water heater meets the National Appliance Energy Conservation Act (NAECA) Energy Factor requirements effective April 16, 2015. Meets the thermal efficiency and standby loss requirements of ASHRAE/IES 90.1., Page 29 1 Turn the power off for 10-20 seconds, then on again to Self diagnostic check has detected clear these error codes. a problem with the gas valve driver circuit, internal microprocessor, or 2 If any of these error codes persist or cannot be cleared, other internal circuits., 2.3 Connecting. The BMS Interface should be connected to the BMS and water heater in the following way: 1. Connect the power supply cable to the connector on the upper right side of the BMS Interface. Connect the other side of the cable to the mains power supply by using a double-pole isolator. Note., Fortunately, most Lochinvar water heaters have a reset button on the thermostat. If not, you can always perform a hard reset of the whole device by flipping the breaker or unplugging it from the outlet. This post will explore which models of Lochinvar have reset buttons, how to perform a hard reset, and what you can explore if a reset fails. , When a hot-water heater goes out and finances are tight, buying a used replacement may seem like the only affordable option. Individuals who take the time to search their local cla..., and an indirect gas fired water heater (FIG’s 2-2 and 2-3). NOTICE See the Water Heater’s Installation and Operation manual for specific piping diagrams that match the inlet / outlet water tappings on the tank to the inlet / outlet water tappings on the water heater. Tapping locations on the water heater may vary by product or manufacturer., Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com Standard Features >o 99% Thermal Efficiency Up t > Modulating Burner Turndown Ratio 10:1 Turndown AWH0400NPM-AWH1000NPM 5:1 Turndown AWH1250NPM-AWH4000NPM > ENERGY STAR Rated > CON·X·US Remote Connect > Indoor/Outdoor Convertible, The Ultimate Water Heater Operating Control • Easy to use - makes setup and service a breeze • 2-line 16-character lcd display of setup, system status and diagnostic data in words, not codes • Water heater pump control: > Pump delay with freeze protection > Pump exercise • High-voltage terminal strip: > 110 Vac input to water heater, Always ensure that your water heater's thermostat and thermistor are working properly. Water Heater FAQs What does code 11 mean on a Rinnai tankless water heater? Code 11 on the Rinnai water heater means the unit is broken due to no gas supply to the tank.. Check and recheck the gas supply to the tank., Lochinvar Copper-Fin II CFN0752 Installation And Operation Manual (80 pages) Lochinvar Water Heater User Manual. Brand: Lochinvar | Category: Water Heater | Size: 7.97 MB., Contact Lochinvar LLC, 300 Maddox Simpson Pkwy, Lebanon, TN 37090. Phone: 1-615-889-8900 or visit our website: www.lochinvar.com. The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed by the warrantor. Dealer replacements are made subject to in-warranty valida ..., The outlet water temperature has exceeded the 210°F manual reset high limit (MRHL) setting. • Verify that the system is full of water and that all air has been …, PRINTED 1215 322886-005. PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE. COMMERCIAL ELECTRIC WATER HEATERS. Thank you for buying this energy efficient water heater. We appreciate your confidence in our products. MODELS HS 50/80/119 Series 100 & HC 50/80/119 Series 100., View and Download Lochinvar EcoShield SHW35-245CE installation, commissioning & maintenance instructions online. Gas Fired Condensing Water Heaters. EcoShield SHW35-245CE water heater pdf manual download. Also for: Ecoshield shw46-325ce, Ecoshield shw61-325ce, Ecoshield shw86-410ce,..., (CHECK LOCAL CODES) INDOOR MODEL - INCLUDES A BUILT-IN TEMPERATURE CONTROLLER AND ADVANCED ... Tankless Residential Water Heater Series. INDOOR MODEL OUTDOOR MODEL 5 Front view Side view 13-7/8" (352mm) 4" (102mm ) 4" (102mm) ... Lochinvar.com ..., Get FREE quotes from licensed Plumbers in your area today. Whether you need a new water heater, a sink repair, or a toilet fixed, We Can Help!