Pentair intelliconnect control system ec-523317Pentair intelliflo pools Pentair intellichem installation and user manual pdf downloadPentair intellichlor ic15 manualslib. Pentair intelliconnect pool control systemPentair intelliconnect owner manual Pentair intelliconnect owner manualPentair compool intellitouch indoor control panel.

Intellichlor troubleshooting. Onboard diagnostics make service simple. Built-in, self-test diagnostics give you the ability to verify correct operation of specific functions, and a diagnostic screen reports failures for troubleshooting and repair. Additional Options / Accessories for Pentair EasyTouch Systems: 3HP Relay for Intellitouch/EasyTouch

Ic40 pentair salt cell intellichlor troubleshooting ic20 pool swimming water. Ic40 salt cell manualPentair intellichlor ic40 salt cell & power center complete free Ic40 salt cell manualIntellichlor ic40 replacement salt cell.

IntelliChlor Power Center Installation Guide Introduction Power Center Overview The IntelliChlor™ system comprises of a Power Center and electrolytic Cell. The Power Center converts AC electrical current to a low voltage DC current required by the IntelliChlor electrolytic cell to operate and create chlorine for the swimming pool and spa. In this case, it is recommended to consult the owner’s manual for troubleshooting options or contact a professional for assistance. The intellichlor is a salt chlorine generator used to convert salt to chlorine, which then sanitizes the water in swimming pools. Shop Salt Test Strips - https://bit.ly/3hzy9FaShop Replacement Salt Cells - https://bit.ly/3HCttIYShop Cyanuric Acid (Stabilizer) Test Kit - https://bit.ly/3...From https://www.justanswer.com/ythiJustAnswer Customer: I have a Pentair Intellichlor 1C40 Power Center and a Pentair 1C40 Intellichlor Chlorine Generator.J...This video demonstrates how to run through diagnostic mode on a Pentair salt cell, and what everything means. If you have any questions please contact us thr...How To Install a Pentair Intellichlor Salt System. The Pentair Intellichlor (SCG) automatically sanitizes your in-ground pool by converting the low concentration level of salt in your pool into free chlorine through electrolysis. This video shows you how to install a Pentair Intellichlor Salt Chlorine Generator (SCG). Note: This video is intended to give you a visual reference to supplement ...Apr 7, 2020 ... Pentair Intellichlor not working? Saltwater Chlorinator Pool/Spa SWG ... Tripping Circuit Breaker Troubleshooting | Mr. Electric. Mr. Electric ...

1. Remove the screw securing the Power Center cover and remove the cover. 2. Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location. There are two (2) screw holes and a keyslot for the top and lower bracket. 3. Drill six ¼ in (6.35 mm) holes. Page 2 This cell must only be used on this model of chlorine generating device. Read the Label, the Installation Manual and Operation Manual of the IC20 chlorine generating device before using. Pentair Water Pool and Spa, Inc. 1620 Hawkins Ave., Sanford, NC 27330 (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021... 1. Remove the screw securing the Power Center cover and remove the cover. 2. Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location. There are two (2) screw holes and a keyslot for the top and lower bracket. 3. Drill six ¼ in (6.35 mm) holes.Pentair Ic20 Ic40 Users Manual IntelliChlor Installatin And User's Guide (Rev D) CE IC20, IC40 to the manual 320bbbda-f407-49d6-a4f7-375e5790a269. 2015-02-06: Pentair Pentair-Ic20-Ic40-Users-Manual-517950 pentair-ic20-ic40-users-manual-517950 pentair pdf . Open the PDF directly: View PDF .An IntelliChlor Electronic Chlorine Generator IntelliChlor system consists of one or more of the following: PC 100 (P/N 520556): Power Center Kit. Provides power and control communication to and from the IntelliChlor cell. IC 20 Cell (P/N 520554): Designed for pools up to 20,000 U.S. gallons (75,000 liters).

IntelliChlor – Guía de instalación y del usuario MEDIDAS DE SEGURIDAD IMPORTANTES Aviso importante: Atención instalador: Este manual contiene información importante sobre la instalación, funcionamiento y uso seguro de este producto. Esta información debería ser entregada al propietario y/o operador de este equipo. Cuando instale y ...The intelliChlor® salt chlorine generator uses common table salt to produce all the chlorine your pool needs, right in your pool - safely, effectively and automatically. • Same sanitation performance as manual chlorine addition without the drawbacks. • No need to buy, transport and store expensive chlorine compounds.Learn how to troubleshoot your iChlor IC30 saltwater generator when it flashes AC and red lights. Get expert advice from other pool owners on Trouble Free Pool.Cold Water: Shows the IntelliChlor SCG power status: • No Light: The IntelliChlor SCG is operating in the normal. temperature range (> 52° F (11° C) • Red: The IntelliChlor SCG is in “Standby” mode (system off, no chlorine production) due to a cold water condition. The. IntelliChlor SCG will resume to normal operation mode,

Derek kolbaba injury 2023.

View online or download PDF (1 MB) Pentair IC40, IntelliChlor IC20, IntelliChlor IC40 User's manual • IC40, IntelliChlor IC20, IntelliChlor IC40 PDF manual download and more Pentair online manuals. Table 2: Troubleshooting the Power CenterPentair Intellichlor Overview - IC15 IC20 IC30 IC40 IC60. In this video I give an overview of how most saltwater chlorinators work. Fix/replace your saltwate...The IntelliChlor and iChlor Electrolytic Cell must be acid cleaned if excessive scale forms between the plates or debris is present. For more information about cleaning the electrolytic cell, refer to the IntelliChlor User’s Guide (P/N 520589) or iChlor Installation and User’s Guide (P/N 522709). Kit Contents: • Stand O-ringThe optimum intellichlor salt level for your basket should be between 2700 and 3600 ppm, which is equivalent to 1.45 and 1.85 kilos / L. ... Pentair Intellichlor Salting Level Problems? You can even use an IntelliChlor scheduling feature to program to how extended the chlorine is active for, or when it wish fully shut off for the night. With ... 4 INTELLICENTER™ Installation & Operation Manual Page Graph View Icon (2nd Graph Icon) Compare Preset Item List 79 - 80 Chemistry (IntelliChem® / IntelliChlor® - PH Measurement) 81 Chemistry (ORP Measurement) 82 Chemistry (Water Balance) 83 Chemistry (IntelliChlor® Salt Chlorine Generator) 84 Status 85 - 86 Settings 87 - 88 Service Mode 89 11. Electrical Specifications. 11. 230 VAC Basic System Wiring. 12. Intelllichlor Power Center with ORP Controller. 14. Pentair IntelliChlor IC40 Pdf User Manuals. View online or download Pentair IntelliChlor IC40 Installation And User Manual.

Salt Cell Troubleshooting with Pentair on the intellichlor ic20 or ic40. July 18, 2016 Ask the Pool Guy. We just had some salt cells requiring maintenance. Pentair has owners manuals and troubleshooting guides on their website, here are a couple for quick reference! Ask the Pool Girl, Ask the Pool Guy, Case Studies, Products, Service Guides ...To troubleshoot and fix the intellichlor flashing red and green lights problem, you need to consider a few potential culprits. Dirty or scaled cells - check the cells to make sure they are not dirty, clogged, or scaled. If they are dirty, clean them with an acid solution by following the manufacturer's instructions. If they are scaling, you ...The Intellichlor ic40 salt cell is designed to work for 10000 hours, on average. This means it'll last you 3 to 5 years easily. If your salt cell is older than that, it will stop producing chlorine. To check the remaining life of your salt cell, press and hold the 'More' button on the control panel. The number of lights that flash as a ...Reason 1: The fuse of the generator does not work. Reason 2: When the cells become obsolete and need replacement. I recommend to check out the following short video to understand how to identify the root causes of cell lights of Pentair Intellichlor chlorinator not working.Shop Salt Test Strips - https://bit.ly/3hzy9FaShop Replacement Salt Cells - https://bit.ly/3HCttIYShop Cyanuric Acid (Stabilizer) Test Kit - https://bit.ly/3...INTELLICHLOR POWER CENTER FOR USE WITH INTELLILCHLOR CHLORINE GENERATOR MODEL IC20, IC40 & IC60 INSTALLATION AND USER'S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. INTELLICHLOR ® Salt Chlorinator Installation Guide. Technical Support Sanford, North Carolina (8 A.M. to 4:30 P.M. ET)Also includes troubleshooting information. • Appendix (page 95): Tablet specifications and operating information. Also, includes information about HomeLogic management and control solutions. • Glossary (page 101): Glossary of terms used in this manual. Technical Support. Sanford, North Carolina (8 A.M. to 5 P.M.) Moorpark, California (8 A.M ...It is compatible with the IntelliChlor IC20, IC40, and IC60 models. Is the Pentair IntelliChlor Power Center a complete salt chlorination system? No, the Power Center is only part of a complete IntelliChlor chlorine generator system. For a complete system you would need to purchase: IntelliChlor IC20 Salt Cell ; IntelliChlor IC40 Salt CellAssign a Pump Circuit:From Settings (3 line icon, top right corner of screen, see page 2) select System Configuration > Pumps. To return to the Home screen, click Settings > Manage My Pool. To configure Pumps, see Settings > System Configuration > Pump. Add Pump:Click Add Pump to add a new pump circuit.IntelliChlor IC20 Generator The economical choice for smaller pools up to 20,000 gallons. Produces up to .70 pounds of chlorine every 24 hours. IntelliChlor IC40 Generator The capacity to sanitize larger residential and smaller commercial pools up to 40,000 gallons. Produces up to 1.40 pounds of chlorine every 24 hours. IntelliChlor IC60 GeneratorWEST ORGIN 520556 Power Center Compatible with IntelliChlor Pool and Spa Automatic Control System Models IC20, IC40, IC60 for Salt Chlorine Generator Systems Aftermarket Part dummy ControlOMatic ChlorMaker Saltwater Chlorine Generation System for Spas and Hot Tubs Up to 2,000 Gallons, Converts Any Spa to Saltwater System

Remove the screw securing the Power Center cover and remove the cover. Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location. There are two (2) screw holes and a key slot for the top and lower bracket. Drill six 1⁄4 inch (6.35 mm) holes.

Apr 20, 2012 ... Pentair Intellichlor Salt Cell: • Cleaning a Pentair Int... Ecomatic ESC Salt system, troubleshooting: • Cleaning a ESC Ecomati... AquaRite ...29 Jun 2012 ... How to Clean a Salt Cell, Brand specific: Pentair Intellichlor Salt Cell: • Cleaning a Pentair Int... Ecomatic ESC Salt system, troubleshooting: ...7. Seneca/SC. May 30, 2017. #1. I'm having an issue with a Pentair IC40. It is a newer version with 4000 hours on it according to it. I was checking it yesterday and found all of the lights out and the fuse blown. I replaced the fuse with another 10 amp fast acting 250v fuse and it promptly blew it. I had the sanitizer output set to 60%.the IntelliChlor chlorinator and pool pump will switch on and off together. Use of chemicals other than those recommended may be hazardous. Follow the Chemical Manufacturer’s Instructions. Install the IntelliChlor unit a minimum of two (2) feet from the heater outlet. It is recommended to install a Pentair Water Pool and Spa®Remove the screw securing the Power Center cover and remove the cover. Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location. There are two (2) screw holes and a keyslot for the top and lower bracket. Drill six 1⁄4 inch (6.35 mm) holes.For troubleshooting information, refer to the IntelliChlor Electronic Chlorine Generator User’s Guide (P/N 520589). Page 46: Service Menu (14/14): Service, Timeout, Auto Service mode, except for switching off equipment manually for emergencies.Pentair INTELLICENTER Installation Manual (16 pages) INDOOR CONTROL PANEL. Brand: Pentair | Category: Control Systems | Size: 2.5 MB. Table of Contents. Table of Contents. 2. Important Warning and Safety Instructions. 3. Indoor Control Panel Installation Overview.Our 3-year old Pentair IntelliChlor iC40 Salt Cell has steadily required more an more salt (up to 4000ppm) even though we regularly clean it. How do you know when the cell needs to be replaced? read morePentair 400k btu/hr manualsPentair ic40 intellichlor Eti® 400 high efficiency gas heaterPentair sta-rite ed series owner's manual pdf download. Pentair eti 400 service manualPentair eti 400 pool heater asme natural g Pentair ic40 intellichlor manual ic20 manuals user installation pagesPentair 400k btu hr manual installation user pages.

Quick weave 27 piece styles.

Insignia tv serial number lookup.

Signs of a potential problem with your salt cell include: Check Salt message displays even though salt levels are fine, Cell Warning light displays constantly, voltage is higher than normal, amperage is irregular, and the SCG isn't producing chlorine. Potential problems that can occur that are unrelated to salt cells are: harsh sunlight and ...Remove the screw securing the Power Center cover and remove the cover. Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location. There are two (2) screw holes and a keyslot for the top and lower bracket. Drill six 1⁄4 inch (6.35 mm) holes.This video will help if your salt cell appears to have no power (all lights out). Try this if your power box does NOT have a glass fuse, but a mini blade fuse.I will show you how to extend the life of your Pentair IntelliChlor IC40 Salt Chlorine Generator by installing a bypass spacer for the cold months of the yea...The IntelliChlor Salt Chlorine Generator (SCG) is designed only to produce chlorine. The SCG does not monitor or control chlorine levels in the pool or spa water. It is the pool owner's responsibility for monitoring and maintaining free chlorine levels at 1-3 ppm for pools and 3-5 ppm for spas.Pentair Intellichlor Power Center Troubleshooting can be done quickly and easily by following the step-by-step instructions provided in the Pentair Intellichlor Installation Guide. Common problems such as low power, abnormal display readings, and communication issues with other devices on the system can be addressed by checking connections ...Remove the screw securing the Power Center cover and remove the cover. Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location. There are two (2) screw holes and a key slot for the top and lower bracket. Drill six 1⁄4 inch (6.35 mm) holes.System Specifications - 110 VAC and 220 VAC Wiring Circuit Protection: Two-pole 20 AMP device at the electrical panel. IntelliChlor Model IC20 Input: 90-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP). Output: 22-39 VDC @ 6 AMPS maximum from the Power Center.† FAQs and Troubleshooting (page 67): Frequently asked questions about using ScreenLogic2 interface. Also includes troubleshooting information. † Glossary (page 71): Glossary of terms used in this manual. Technical Support Sanford, North Carolina (8 A.M. to 5 P.M.) Moorpark, California (8 A.M. to 5 P.M.) Phone: (800) 831-7133 Fax: …May 30, 2021 ... I hope this video helps you determine where your problem is with suction and it not dosing muratic acid or liquid chlorine as it used to .Hayward VS900 Manual - 1.85HP VSP Pump; Hayward VS950 Manual - 2.7HP VSP Pump; Jandy. Jandy AquaLink RS Manual; Jandy AquaPalm Manual; Jandy ePump Regulators; Pentair. Pentair Challenger Pump Operation - Installation & Operating; Pentair Intellichlor Flow-Temperature Switch Substitution Kit Instructions; Pentair Intellichlor IC15, IC20 ... ….

Page 4: Introduction. Introduction This manual describes how to remove and install the EasyTouch and IntelliTouch IntelliChlor Salt Chlorine Generator (SCG) replacement parts. Summary Installation Steps • Before removing and replacing part first switch OFF the main power to the EasyTouch/IntelliTouch load center. Specific Troubleshooting Steps For Each Cause Listed Above. To troubleshoot and fix the intellichlor flashing red and green lights problem, you need to consider a few potential culprits. Dirty or scaled cells – check the cells to make sure they are not dirty, clogged, or scaled. Reinstall the Power Center cover and secure with the cover screw. 10. The Power Center installation is complete. For IntelliChlor operating information, refer to the IntelliChlor User’s Guide (P/N 520848). Connect incoming ground wire to GROUND lug. Attach incoming power wires (12-14 AWG 3-wire) to Power Center.This instructional video demonstrates what to do to fix your salt cell if it does not display any lights. there are three demonstrations for the 3 types of n...Pentair IntelliChlor IC15 Salt Cell with 15 Foot Cable and External Power Supply sanitizes smaller pools up to 15,000 gallons. For above ground pools up to 15,000 gallons. Cell and control panel in one unit. Includes external power supply. Titanium electrode cell blades. Step 19. Glue the salt cell unions into the section of return line that was removed above. Slide cell into place and tighten unions. This installation had 1.5" plumbing so we had to use a reducer on the 2" unions. All installations will be little different and being a little creative will come in handy. If you are using an IntelliChlor salt chlorine generator, adjust the salt levels to the recommended levels in the IntelliChlor (SCG) Installation and User's Guide (P/N 520589). During normal operation, no user input is required, the Commercial IntelliChem controller will automatically sense ORP and pH levels.Hayward VS900 Manual - 1.85HP VSP Pump; Hayward VS950 Manual - 2.7HP VSP Pump; Jandy. Jandy AquaLink RS Manual; Jandy AquaPalm Manual; Jandy ePump Regulators; Pentair. Pentair Challenger Pump Operation - Installation & Operating; Pentair Intellichlor Flow-Temperature Switch Substitution Kit Instructions; Pentair Intellichlor IC15, IC20 ... Intellichlor troubleshooting, Our Price: $738.58. IntelliChem can work independently or in conjunction with other Pentair automation products. It's built-in Langelier Saturation Index calculator lets pool. owners know when the water is in or out of balance. IntelliChem uses the same technology found in commercial installations, water parks, hotel and community pools., Before you put down that deposit on a home, don't forget to carefully inspect it—even if it appears to be in good condition. Some problems might go unnoticed, and you want to spot ..., My Intellichlor Power Center was installed with pool, about 10 years ago. In July, 2022 I replaced IC 20 salt generator with generic replacement (CFICGEN40) and it has worked fine since then. Now there are no lights on at the salt generator. The led light in the power cell is on so the fuse is good. The power cell output is supposed to be 20 ..., 1.1 No Power Supply. 1.2 Low Chlorine Production. 2 Troubleshooting Steps. 2.1 Check Power Supply Connection. 2.2 Inspect Cell For Build-up. 3 Preventive Maintenance. 3.1 Regular Cleaning And Inspection. 3.2 Monitoring Chlorine Levels. 4 Contacting Professional Help. 4.1 When To Seek Professional Assistance. 4.2 Choosing The Right Service Provider., IntelliChlor® Salt Chlorinator uses common table salt to produce all the chlorine a pool needs, safely, effectively, and automatically. Same sanitation performance as manual chlorine addition without the drawbacks. No need for customers to buy, transport and store chlorine compounds. Electrolytic chlorine generation (or salt chlorine ..., In this troubleshooting guide, we'll address common problems with the IntelliChlor unit, a crucial chlorine generator in your pool and spa system. Whether you're experiencing power issues, flow light concerns, or problems with chlorine production, we've got you covered. IntelliChlor Unit Has No Power: Issue: Fuse in the power center is open., Salt generator chlorine gal 25k chlorinator sox export 1012 1013 1033 40k system pool360 poolcorpPentair ichlor 30 manual / salt cell troubleshooting with pentair on the intellichlor ic20 or Pentair chlorine generatorIchlor salt chlorine generator manual. ChlorMaker Owners Manual - Spa Chlorine Generators | Manualzz Check Details, WEBSITE: http://www.swimmingpoollearning.com/YouTube Video Index -- A list of all of my videos: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-re..., A cell alert indicates that the salt cell has slowed or stopped working. It doesn’t necessarily mean the cell is faulty and needs replacement. Instead, it might just need a thorough cleaning. Important: Many models display the Inspect Cell alert every 500 hours as a cleaning reminder., Jan 26, 2021 · Install anchors if necessary and one screw for each bracket keyslot location. Position each Power Center keyslot (top and lower) slot over the two mounting screws just installed. Tighten the two screws to secure the enclosure. Install and tighten four mounting screws (two in the top and two in the lower bracket). , I have trouble with my intellichlor IC40. the low chlorine tells me the generator is not producing any chlorine at all. Sometimes the flow light is not on,I am not sure if it needs to be lighted all the time the pump is running or not.The salt is on yellow, though the salt level in the pool reads between 3700 and 4000., the IntelliChlor chlorinator and pool pump will switch on and off together. Use of chemicals other than those recommended may be hazardous. Follow the Chemical Manufacturer's Instructions. Install the IntelliChlor unit a minimum of two (2) feet from the heater outlet. It is recommended to install a Pentair Water Pool and Spa®, Ic40 pentair salt cell intellichlor troubleshooting ic20 pool swimming water. Ic40 salt cell manualPentair intellichlor ic40 salt cell & power center complete free Ic40 salt cell manualIntellichlor ic40 replacement salt cell., If you have any questions please contact us through our website at: https://www.poolspecialists.com/, However, when using the IntelliChlor, a good starting point is to set the chlorine output between 10 and 20 percent of the recommended manual chlorine dose, which you can calculate by taking the volume of the pool and multiplying it by the desired amount of chlorine. Keep in mind that you may have to adjust the output setting over time to find ..., May 15, 2019 ... Ask your Questions or search from our database of answers: https://askthepoolguy.com/questions/ask/ Make sure you Subscribe so you get your ..., i<br /> Contents<br /> Important Warnings and Safety Instructions ..... iii - iv<br />, Very happy with my Pentair IntelliChlor! If this one lasts as long as our last one did, I will be ecstatic! After our original Pentair unit slowly faded beginning mid-summer 2014 (cell indicator light continuously flashing), it was still able to maintain chlorine at proper levels for the remainder of the season and even limped along over the subsequent winter (we live in the sunny south and ..., Mar 2, 2011 · Salt light flashing green: This means the salt is too high. But you knew that already. Cell light flashing green: means inspect the cell. Power light red: Means that the IC-40 needs service. I'd start by removing the cell and see if there is calcium build up on the blades. , Pool Water Preparation. 12. Determining Pool Size (Liters of Water in Your Pool) 12. Approximate Pounds (Lbs) / Kilogram (Kg) of Salt Needed. 13. Approximate Amount of Stabilizer (Cyanuric Acid) 13. Operating the Salt Chlorinator., Are you experiencing issues with your Delonghi appliance? Don’t fret. Delonghi has made troubleshooting and repairs easier than ever with their comprehensive manuals available onli..., Are you having trouble with your Maytag washer? Don’t worry, you’re not alone. Many people have experienced issues with their Maytag washers, and it can be difficult to know where ..., There’s a couple of basics to troubleshooting pretty much anything. First, keep an open mind. Second, troubleshoot systematically. In this case, that means looking systematically a..., In this troubleshooting guide, we'll address common problems with the IntelliChlor unit, a crucial chlorine generator in your pool and spa system. Whether you're experiencing power issues, flow light concerns, or problems with chlorine production, we've got you covered. IntelliChlor Unit Has No Power: Issue: Fuse in the power center is open., Troubleshooting ideas for a well pump include checking the electrical system, ensuring the structural integrity of individual pump components and verifying that the well’s depth-to..., Remove the screw securing the Power Center cover and remove the cover. Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location. There are two (2) screw holes and a key slot for the top and lower bracket. Drill six 1⁄4 inch (6.35 mm) holes., We would like to show you a description here but the site won't allow us., The ScreenLogic2 Interface allows you to control the key functions of a pool or spa using the IntelliTouch® and EasyTouch® control systems. You can remotely manage, monitor and control via mobile device. Easily change, track and monitor history of pH and ORP levels when using the IntelliChem® Water Chemistry Controller with IntelliTouch® or ..., 31. Intellichlor "Dummy" Cell. 32. Selecting Model Size - Intellichlor Model IC20, IC40, IC60. 32. Installing the Intellichlor Cell Assembly. Connecting the Cell Power Cable to the Power Center. Connecting the Power Supply Cable to the IC15 Cell. Connecting IC20, IC40, IC60 Power Center to Intellitouch, Easytouch or Suntouch System., IntelliChlor® IC20/IC40/IC60 and Controller System Part Numbers Refer to the following part numbers when configuring the IntelliChlor Electronic Chlorine Generator and the IntelliChlor Power Center with an IntelliTouch, EasyTouch or SunTouch system. Technical Support Sanford, North Carolina (8 A.M. to 5 P.M. Eastern Time), When troubleshooting any Pentair Intellichlor flow switch, it is important to first check the power supply connections and ensure that all wires are properly connected. If the problem persists, it may be necessary to inspect the wiring of the flow switch for any possible damage. Additionally, checking for debris in or around the valve can help ..., the IntelliChlor chlorinator and pool pump will switch on and off together. Use of chemicals other than those recommended may be hazardous. Follow the Chemical Manufacturer's Instructions. Install the IntelliChlor unit a minimum of two (2) feet from the heater outlet. It is recommended to install a Pentair Water Pool and Spa®, See “Troubleshooting” on page 46 for more information. ... If you are using an IntelliChlor salt chlorine generator, adjust the salt levels to the recommended levels in the IntelliChlor (SCG) Installation and User’s Guide (P/N .