Chlorinator off high salt amps

It keeps reading chlorinator off/high salt/amps. 4 days - Answered by a verified Pool and Spa Expert We use cookies to give you the best possible experience on our website. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them.

Chlorinator off high salt amps. Problem #3: Low Water Flow. Low water flow is another common issue that can occur with salt cells. If the water flow is too low, the salt cell may not be able to generate enough chlorine to keep the water clean.This can be caused by clogged filters, a malfunctioning water flow valve, or a dirty cell.. To troubleshoot this issue, start by inspecting and …

JustAnswer-Q&A. 8.12K subscribers. Subscribed. 0. 1.2K views 2 years ago. From https://www.justanswer.com/ythi JustAnswer Customer from San Antonio, TX: I have the "Chlorinator off High...

Aug 23, 2009 ... ... Salt, High Salt, and ... The Goldline tech said the “High Salt/Amps ... Make sure you turn your chlorinator Off for 24 hours every time you add salt ...In some models, the salt generator will turn off for protection. This means that the salt content entering the generator is too high and chlorine production is hindered due to salt overload. You want to make sure the salt levels remain within the range or the ideal level to achieve optimal chlorine generation for your pool. 2. TemperatureReset Average Salt & Adjust Chlorinator Output. 6. Adjust ORP Set Points & Adjust Heater Set Points. 8. Clear Inspect Cell Message & Set a Pump Schedule. 10. Change VSP Speed Settings & Clean the Turbo Cell. 12.Mar 7, 2015 ... In this video you will learn how to ascertain whether your salt cell (salt chlorinator) is working and producing chlorine.Timer stopped working but overall function is great. Timer gets stuck when tries to switch on automatically on Waterco Hydrochlor TS salt chlorinator. happened after 6 years after working well. Waterco support was incredible! Fixed it under warranty even though outside the warranty period. Show details.If all zeros or if Chlorinator Off Percentage Met, press ~+ key. IF, after a short countdown delay, the display does not revert to zeros, refer to step 3. NOTE: The main circulation pump MUST be ON and the chlorinator AND flow switch MUST have flow to successfully complete this process. 2 Above is an example of the updated instant salt reading ...Nov 12, 2021 ... ... Pools, Inc.•530K views · 12:08. Go to channel · Chlorinator Off No Cell Power - DIY Repair. FiveAble•90K views · 1:54. Go to channel &midd...chlorine production by measuring the amps drawn by the chlorinator cell in each polarity. 1. Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. 2. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it from the port at the bottom of the power pack.

The aquapod is saying high salt/high amps, chlorinator off. The diagnostics is showing 2700 ppm salt (not high) and a salt test strip showed something …Low salt. The Salt Cell needs a certain amount of salt in the water to convert the salty water to chlorine. The correct salt level is important to cell life and the effective operation of your chlorinator. A typical pool of around 50,000 litres requires 200kg of salt to initially set-up the pool to 4,000ppm.In fact, most of the time, they’re easier. BUT they are a little different. 1. Inspect regularly for scale. One of the biggest problems with salt chlorine generators is that they tend to produce a lot of scaling (or calcium deposits). To keep this at a manageable level, check your generator every 2-3 months.Sep 14, 2006 · I have a T-Cell-15, My pool control panel says "Pool Chlorinator 30%" "Chlorinator Off - High Salt Amps" Screen Says "Main Software Revision 2.85" "Display Software Revision 3.11" What do you suggest so that I can get my pool back to salt. Aqua Plus Control Panel.....last year it was saying "no cell power" but doesn't anymore. Summer Operation. You should set your chlorinator to operate for 8 to 10 hours per day. Ideally, run it for 4-5 hours in the morning (say 8-12pm) and 4-5 hours in the evening (say 6.00-11pm). In extremely hot weather it may be necessary to extend the running time if you find that the free chlorine level is too low.

Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...High Salt/Amps The “Chlorinator Off High Salt” warning comes on when the current exceeds 8 amps regardless of the salt level. This can be caused by high salt but also by high water temperatures. If it says high salt, the amps were above 8.0. If the volts are more than 32 at any point, the circuit board is probably damaged.Turn the chlorinator cell to “off” and turn pump switch to “man” to start filtration system for a minimum period of 24 hours. After the 24 hour period, or if the salt is at the required level turn the cell switch to “on” and the pump switch to “manual” or “auto”. RECOMMENDED LEVELS TO ENSURE OPTIMAL OPERATION.Chlorinator Off - Test Salt Level Message Maximum Current (Amps) before shutdown T-Cell 3: 5.50 T Cell 9: 10.00 T-Cell 5: 6.75 T Cell 15: 10.00 Before operation, the Aqua Rite must be configured for the chlorinator cell that will …How does sodium isethionate work in cleansers? Learn about how sodium isethionate works in cleansers at HowStuffWorks. Advertisement An ancient legend claims that Roman women disco...

Homicide in west palm beach.

ProLogic: How It Works. • All ProLogic systems are salt chlorination ready and can control 4-16 high voltage relays, 3-4 valve actuators and 1-2 heaters. • These systems can manage: Hayward Variable Speed Pumps, ColorLogic Lighting, Sense & Dispense, AquaConnect Homenet, as well as a wide variety of remotes.The calcium level. The chlorine level in the pool. Salt Levels. If you are having problems with your chlorine generator, the first thing to do is to make sure you have enough salt in the pool water. The Zodiac …Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...#SWIMMINGPOOL #MAINTENANCE #TROUBLEFREEPOOLFix the common chlorinator off - no flow error. DIY it for huge savings. Do not call the pool company unless you... My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm.

Recommended phosphate levels in the pool water are below 200 ppb. Stabiliser: The chlorine gets broken down fast by UV. The way to stop this is to use stabiliser which acts as a sunscreen for the pool water. Recommended stabiliser levels are 30 -50 ppm. PH: Chlorine is more effective when the PH is low.Apr 5, 2020 ... SWIMMINGPOOL #MAINTENANCE #TROUBLEFREEPOOL Fix the common chlorinator off - no flow error. DIY it for huge savings.If the amps on either reading show zero (0), then you should replace your Main PC Board (GLX-PCB-RITE). If the amps show a reading that isn’t within range, then you should replace your Turbo Cell. High Salt LED ON. The High Salt LED stays on when: The cell amperage is above the maximum limit. You have too much salt in your pool.A salt water chlorinated pool requires much less attention than a chlorine pool. A salt water pool provides a more comfortable swimming environment. Easy to Program Hydrochlor TS features an easy to use analogue timer. ... Just move the tappets to either the on or off position to program the chlorinator. Battery Back Up A battery backup is ...The aquapod is saying high salt/high amps, chlorinator off. The diagnostics is showing 2700 ppm salt (not high) and a salt test strip showed something …May 18, 2019 · I have a Hayward goldline pro logic with a message that reads chlorinator off high salt amps. The values are at 40.58v, 10.08a. ... System check, chlorinator off very ... SKU # PLC1400. The Jandy AquaPure ® salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. Rely on its sturdy design and simple features to create your saltwater oasis. Read more. Find a Dealer.Sep 5, 2023 · TCELLS340 generates up to 1.45 lbs. of chlorine per day at high salt or up to 0.725 lbs at low salt levels. TCELLS325 generates up to 0.98 lbs. of chlorine per day at high salt or up to 0.49 lbs at low salt levels. TCELLS315 generates up to 0.53 lbs. of chlorine per day at high salt or up to 0.265 lbs at low salt levels. Aquarite Cell Plates Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...What is you actual salt level, not from the units readout but actual. If the salt is low (1900) the unit will be working harder to try and produce the chlorine which can harm the power unit. Water is more conductive with 3500 salt so less power Volts and amps required. A guy quite recently published a schematic on here and that showed 22.8vThe E Series Salt Chlorinator offers affordable, reverse polarity self cleaning technology in a simple to use, easy to install yet robust and reliable product. ... 8.9 amps Equipment: Clock timer settings: 2 timers Video. E25 - Setting Output. Play. Video. E25 - Connecting the Cell. Play. Video. E25 - Connecting Pump. Play.

Apr 5, 2020 ... SWIMMINGPOOL #MAINTENANCE #TROUBLEFREEPOOL Fix the common chlorinator off - no flow error. DIY it for huge savings.

You only need to enjoy the spa-like feel of the clear, soft, and clean water. While this is a good option for a salt water chlorinator and rightfully in the top 50% of the 24 salt pool systems we tested, it is on the pricier side and has been known to have issues with durability past 1 year of use. 11. Intex Krystal.Looking for a replacement cell for your AquaRite salt pool chlorine generator? Consider the Hayward T-Cell-15 replacement cell! ... My pool control panel says "Pool Chlorinator 30%" "Chlorinator Off - High Salt Amps" Screen Says "Main Software Revision 2.85" "Display Software Revision 3.11" What do you suggest so that I can get …Low salt. The Salt Cell needs a certain amount of salt in the water to convert the salty water to chlorine. The correct salt level is important to cell life and the effective operation of your chlorinator. A typical pool of around 50,000 litres requires 200kg of salt to initially set up the pool to 4,000ppm.Downloads: full (1000x714) | large (980x700) | medium (300x214) | thumbnail (150x150) AutoPilot ® has been the leading swimming pool salt chlorine generator manufacturer since 1976, offering a full range of units to meet any chlorine need. AutoPilot ® can maintain anything from small above ground pools up to very large commercial facilities.The cell amperage is another number that is sometimes on a saltwater generator display screen. It’s a measure of the amount of electric current entering your salt cell. Now, the amperage readings differ depending on the type of cell you’re using. There are four different kinds of cells; T-Cell 3, T-Cell 5, T-Cell 9, and T-Cell 15.When salt reading drop bellow 2300 ppm is Aqua Rite will shoot down output to cell( generating LED off). Chlorine generation will stop even actual salt level in pool is 2500-3400 ppm. But cell is still OK and can generate chlorine. Problem is caused by salinity sensor that is part of cell, so we need to clean,calibrate it or replaced.Salt has its uses: It flavors food, keeps us from dying of a sodium deficiency (rare but real), and, well, that’s about it. And that’s true whether the salt is white or pink. Salt ... Page 20: Chlorinator Off, High Salt/Amps 2. Chlorinator OFF, High Salt/Amps (cont.) The salt concentration will need to reduced. To calculate how much water to drain, follow the formula provided below (Proportional Method): Step 2D Part I Part 1: Take the average depth of the pool in inches and multiply that by 3200. Page 21: Chlorinator Off ... Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...

How many stamps on a manilla envelope.

Sunset lounge bottoms up.

I was still getting the "High Salt/Amps" message. I installed the new display and corrected the day and time. All other settings were still correct, including the Cell configuration (T-15). I checked the Volts and Amps and Salt levels. The readings were the same for both + and - polarities: 40.62V, 10.04A, and 1900PPM.The EcoChlor Titanium Edition self cleaning salt water chlorinator is a complete solution for replacing an old chlorinator or converting a pool to saltwater chlorination for the first time. It is intended for use in pools up to 80,000 (tropical)- 150,000 (temperate) litres in volume. It is designed and ested to perform in the toughest of Australia climates and …for the correct period and turns off the electrolytic cell, preventing excessive build ... constructed to withstand high temperature and UV radiation in the harsh Australian environment. ... V35 Viron Salt Chlorinator 10816 35gm/h 130,000 80,000 8 amps 10 amps V45 Viron Salt Chlorinator 10817 45gm/h 170,000 105,000 8 amps 10 ampsPush 3, Cell Amperage - The cell's average amperage when chlorine is being generated varies with the size of cell installed: T-15 is 3.1 to 8.0 amps; T-9 is 2.3 to 6.7 amps; T-5 is 1.9 to 5.7 amps; and t-3 is 1.3 to 4.5 amps. When the cell is not generating chlorine the amperage is 0.Split from the Aqua-logic salt too high-cholrinator off high salt/amps topic. Bama I'm having the same exact problem, but did not find any weak or burnt looking soldering points...Also, the back of my board looks a little different then the one pictured. …The Ezi Salt Saltwater Chlorinator will convert ordinary saltwater into 100% safe usable chlorine, to effectively sanitise your pool. 1. The user friendly menu with built in clocks and timers means all you need to do is plug it in, set it up and add salt. 2. The reverse polarity electrode cuts down dramatically on maintenance. 3.Low salt. The Salt Cell needs a certain amount of salt in the water to convert the salty water to chlorine. The correct salt level is important to cell life and the effective operation of your chlorinator. A typical pool of around 50,000 litres requires 200kg of salt to initially set-up the pool to 4,000ppm.Astral Pool VX Salt Chlorinator Manual Summary. The user manual for the AstralPool VX salt chlorinator provides detailed information on the installation, operation, maintenance, and troubleshooting of the product. The manual begins with a general overview of the product, followed by instructions for the installation of the control box and the cell.The “High Salt” light will stay on for several reasons including: cell amperage is above the maximum limit, the control is set to the wrong turbo cell, or, most …Check and balance your pool chemistry: Regularly test and balance your pool chemistry, paying attention to pH levels and cyanuric acid levels. High pH or low cyanuric acid can impact chlorine effectiveness. Maintain a pH level of 7.2-7.6 and a CYA level of 30-50 ppm to reduce strain on the salt cell.I have a T-Cell-15, My pool control panel says "Pool Chlorinator 30%" "Chlorinator Off - High Salt Amps" Screen Says "Main Software Revision 2.85" "Display Software Revision 3.11" What do you suggest so that I can get my pool back to salt. Aqua Plus Control Panel.....last year it was saying "no cell power" but doesn't anymore.It would suggest the salt levels are too high based on the error reporting, drain some of the water and top it up and this will reduce your salt level, you want it ideally less than 3500 … ….

I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read more chlorine production by measuring the amps drawn by the chlorinator cell in each polarity. 1. Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. 2. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it from the port at the bottom of the power pack. You only need to enjoy the spa-like feel of the clear, soft, and clean water. While this is a good option for a salt water chlorinator and rightfully in the top 50% of the 24 salt pool systems we tested, it is on the pricier side and has been known to have issues with durability past 1 year of use. 11. Intex Krystal.Salt is a common substance that is found in a wide variety of foods. Learn about salt, the properties of salt and the manufacturing of salt. Advertisement Salt is salt, right? When... Problem #2: High Salt Levels. High salt levels in your pool can cause damage to your salt cell and reduce its lifespan. It can also cause skin and eye irritation for swimmers. If you’re noticing high salt levels, start by testing the water and checking the cell for buildup or corrosion. If there is buildup, clean the cell using a soft brush ... Set TurboCell® Type & Reset Average Salt 10-11 Adjust Chlorine Output & Clean TurboCell 12-15 Troubleshooting: Pg. 16-38 1. Check Salt & Inspect Cell: flashing or ON 17-20 2. High Salt: LED ON 21-25 3. No Flow: LED flashing or ON 26-30 4. Display ONLY, Lights ONLY, or Neither 31-36 5. LCD: Displaying HOT or COLD _ 37-38 STEP 1C: Starting with the average salt reading. Turn the switch to ‘Off’, then back to ‘Auto’. Wait for the relay to click (about 5 to 10 seconds). STEP 2: Press the ‘Diagnostics’ button 5 times, this will bring up the instant salt reading. The instant salt reading will start as - 0.Salt water chlorinators started to be used about 50 years ago, and the use of minerals instead of salt started in about 2006. Both systems use the same concept: salt (sodium chloride) or minerals (typically a blend of magnesium, potassium, and sodium chlorides) are dissolved into the water to the level required by the chlorinator.Then the …The Aqua Plus is designed to handle the purification needs of most residential swimming pools up to 40,000 gallons (150,000 liters), or the needs of most commercial pools up to 25,000 gallons (95,000 liters). The AQ-PLUS-20 should be used for pools up to 20,000 gallons (75,000 liters).How does sodium isethionate work in cleansers? Learn about how sodium isethionate works in cleansers at HowStuffWorks. Advertisement An ancient legend claims that Roman women disco... Chlorinator off high salt amps, Sodium Phosphate Rectal: learn about side effects, dosage, special precautions, and more on MedlinePlus Rectal sodium phosphate is used to treat constipation that happens from time..., Too high - add muriatic acid Alkalinity 80 - 120 ppm Salt 2700 - 3400 ppm Add salt as required to increase. ... determined by turning the equipment off and on, then the user is encouraged to try to correct the interfer- ... the salt into free chlorine which kills bacteria and algae in the pool/spa. Chlorine will revert back to sodium chloride ..., When salt reading drop bellow 2300 ppm is Aqua Rite will shoot down output to cell( generating LED off). Chlorine generation will stop even actual salt level in pool is 2500-3400 ppm. But cell is still OK and can generate chlorine. Problem is caused by salinity sensor that is part of cell, so we need to clean,calibrate it or replaced., Turn the chlorinator cell to “off” and turn pump switch to “man” to start filtration system for a minimum period of 24 hours. After the 24 hour period, or if the salt is at the required level turn the cell switch to “on” and the pump switch to “manual” or “auto”. RECOMMENDED LEVELS TO ENSURE OPTIMAL OPERATION., In fact, most of the time, they’re easier. BUT they are a little different. 1. Inspect regularly for scale. One of the biggest problems with salt chlorine generators is that they tend to produce a lot of scaling (or calcium deposits). To keep this at a manageable level, check your generator every 2-3 months., Split from the Aqua-logic salt too high-cholrinator off high salt/amps topic. Bama I'm having the same exact problem, but did not find any weak or burnt..., I recently used chlorine bleach to clean the siding on my house, and I was amazed at how well it worked! What is bleach? How does it remove stains? Is the chlorine in bleach the sa..., If all zeros or if Chlorinator Off Percentage Met, press ~+ key. IF, after a short countdown delay, the display does not revert to zeros, refer to step 3. NOTE: The main circulation pump MUST be ON and the chlorinator AND flow switch MUST have flow to successfully complete this process. 2 Above is an example of the updated instant salt reading ... , I have the "Chlorinator off High salt/amps" message. Contractor's Assistant: I'll do all I can to help. How long have you been dealing with this? I replaced the CG a couple of months ago and currently it is reporting 4600 PPM on the salt. just this past week, and the pool turned green on me wed-today I shocked at lunch to get the green cleared up, but bigger concern is the CG not generating, Himalayan pink salt lamps are beautiful, but do they really have health benefits? We asked the experts if salt lamp benefits are real or just another fad. There are a lot of holist..., Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ..., I just replaced my T-cell 97 Turbo cell with a new T-cell 25. When the system begins to run I get this message, "Chlorinator Off High Salt/Amps." Then later int the messages I retrieve, "Check System High Salt/Amps." I checked the instant salt reading and it is 4690, which I know is way too great. I..., Sodium Phosphate: learn about side effects, dosage, special precautions, and more on MedlinePlus Sodium phosphate can cause serious kidney damage and possibly death. In some cases,..., #SWIMMINGPOOL #MAINTENANCE #TROUBLEFREEPOOLFix the common chlorinator off - no flow error. DIY it for huge savings. Do not call the pool company unless you..., Saltmate saltwater electrolytic cells are constructed with premium grade high production material and are designed with high flow rate parallel plates. All Saltmate saltwater chlorinators can be installed onto new or existing pools without the need to change any other filtration equipment and are also compatible with mineral salt blends. Models., AutoPilot Pool Pilot Tech Support & Troubleshooting Request. SaltPoolGuys.com is the leading authorized dealer of AutoPilot Pool Pilot salt systems. We stock a full selection of replacement parts & cells with shipping nationwide. As a service to AutoPilot Pool Pilot salt chlorine generator owners we offer free technical support to help with ..., Help please! My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm., If the chlorine is still low or hasn’t increased, try increasing the power to 70%. If the chlorine level is too high, back off the power. Keep adjusting and testing until you have a stable chlorine level (which should be 3-5 ppm). 7) Algae Using Up Chlorine . There may not actually be anything wrong with your salt cell or chlorinator. , Saltmate saltwater electrolytic cells are constructed with premium grade high production material and are designed with high flow rate parallel plates. All Saltmate saltwater chlorinators can be installed onto new or existing pools without the need to change any other filtration equipment and are also compatible with mineral salt blends. Models., Switch off the filter pump and chlorinator and close the necessary valves. Unplug the cell terminal cap. Unscrew the electrode retaining ring and remove the electrode. Immerse the electrode in a self-cleaning solution, …, I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read more, E Series Salt Chlorinator E SERIES SALT CHLORINATOR Automatically disinfects and sanitises pool and ... AstralPool’s premium chlorinators to ensure high levels of ... E35 2 timer periods/day 35 gms/hr 4,100 to 8000 120,000 75,000 8 amps 225 175 318 296 266 256 108 150 124 To find out more visit astralpool.com.au 0908161, Apr 17, 2012 · Split from the Aqua-logic salt too high-cholrinator off high salt/amps topic. Bama I'm having the same exact problem, but did not find any weak or burnt... , Runs cooler than other chlorinators on the market and reduces voltage ripple. Can be used in water that has a very high salt content. Ease of operation. Adjustable cleaning cycles. 3000 to 35000 ppm Salt (can be used in sea water) LED indicator lights. Low salt disables output. Electronic flow sensor and fault light., Check Salt High Salt Inspect Cell Maximum Current (Amps) before shutdown T-Cell 3: 4.15 T-Cell 5: 6.40 T Cell 9: T Cell 15: 9.50 10.00 If salt level is above the range, partially drain pool and/or spa and refill with fresh water to achieve a salt level of 3200ppm. ( RULE of THUMB: Each inch of water drained will reduce the salt level IOOppm ..., The optimal voltage range for chlorinator cells varies depending on the specific make and model. It is crucial to consult the manufacturer’s documentation or user manual for the recommended voltage range. Generally, the voltage range falls between 5 to 7 volts for most chlorinator cells. Operating the cell within the specified voltage range ..., Chlorinator Off - High Salt/Amps Error Message Test the salt level in the pool using a suitable tester. Be sure the tester has been calibrated and is clean. Pool water will have to be removed and fresh water added to reduce the last level to the 3200 PPM level if found to be higher. Check to make sure system is configured for correct model cell., Technical Specifications. Produces 25 grams of chlorine gas per hour. Ideal salt level 3000ppm with water at 25°C. Suits outdoor pools up to 90,000 litres. Suits indoor pools up to 150,000 litres. Cell has 50mm unions (reducers not included) 5 …, • The AquaRite 100 Salt Chlorine Generator is designed to convert 99% pure salt into chlorine gas(CL. 2 (g)). • When CL. 2 (g) is dissolved in water it creates Hypochlorous Acid (HOCL) to sanitize the pool. • The conversionoccurs in the electrolytic cell, also known as the cell (used throughout this guide)., Check Salt High Salt Inspect Cell Maximum Current (Amps) before shutdown T-Cell 3: 4.15 T-Cell 5: 6.40 T Cell 9: T Cell 15: 9.50 10.00 If salt level is above the range, partially drain pool and/or spa and refill with fresh water to achieve a salt level of 3200ppm. ( RULE of THUMB: Each inch of water drained will reduce the salt level IOOppm ..., Salt Chlorinators are designed to assist with the precise ... A high performance and technically sophisticated chlorinator, featuring bluetooth ... VX 7T Chlorinator 25 gms/hr 96,000 50,000 4 timers 3,000 to 8,000 4,000 8.9 amps n/a VX 9T Chlorinator 30 gms/hr 120,000 75,000 4 timers 3,000 to 8,000 4,000 8.9 amps n/a, I was still getting the "High Salt/Amps" message. I installed the new display and corrected the day and time. All other settings were still correct, including the Cell configuration (T-15). I checked the Volts and Amps and Salt levels. The readings were the same for both + and - polarities: 40.62V, 10.04A, and 1900PPM., Chlorinator Off - High Salt/Amps Error Message Test the salt level in the pool using a suitable tester. Be sure the tester has been calibrated and is clean. Pool water will have to be removed and fresh water added to reduce the last level to the 3200 PPM level if found to be higher. Check to make sure system is configured for correct model cell.